Research of Current Distribution in IGBT Modules with Multiple Chips in Parallel

In the present paper studies of the module internal switching losses are shown. Emphasis is on paralleling of the chips in an IGBT module. The analysis started with simulations. With the aid of a miniaturized Rogowski coil, the loss distribution in the module was determined. With an infrared measurement, the effects of the module internal switching symmetry was verified. In the design of a module symmetry of losses is important. But a dynamic symmetry of 100% is not realistic. For evaluation of a module it is necessary to simulate and measure the module. It is not possible to judge a complex lay out without such an in depth investigation. Measurement of the device with an improved Rogowski coil have shown that loss distribution even in a visible asymmetric module differ only 2-5%. With infrared - measurement it could be verified that minor module internal asymmetries are neglectable. The heat sink geometry in addition to the static losses has a larger influence to the total losses and the temperature distribution.