H4-PFC Infineon 1600W Server PSU
 All Data Structures Files Functions Variables Typedefs Enumerations Enumerator Macros Groups Pages
Background

Files

file  init_bckgnd_funct.c
 Functions for SW initialization and running in the background during operation.
 
file  init_bckgnd_funct.h
 Header of the functions for SW initialization and running in the background during operation.
 

Functions

void MATH_DIV_config ()
 DIV kernel of the MATH co-processor initialization.
Used in the input RMS feedforward. More...
 
void temperature_sense_enable (void)
 Enable the internal temperature sensor and set the measurement pointer. More...
 
void control_loop_init ()
 Assign value to the coefficients of voltage and current loops.
Reset the state and output of both controllers. More...
 
void IIR_param_init (void)
 IIR coefficients initialization.
IIR cascaded low-pass filter of the AC voltage to obtain the RMS value.
IIR notch filter of the DC voltage to remove 100/120Hz ripple.
Sampling frequency of both filters is 3250Hz, every 2 cycles of CCU40.CC41 @ 6.5kHz. More...
 
void time_counter ()
 Time counter is a background process to count "real-time" in the application. More...
 
void delay_100us (uint32_t time)
 Delay function. More...
 
void input_voltage_observer ()
 BOP protection, checking AVG input voltage.
The function modifies the control status register. More...
 
void fan_control_temp_protection ()
 Temperature monitoring: protection and fan control. More...
 

Variables

volatile bool power_stage_ON = false
 

AC voltage filter variables

volatile IIR_lowpass_int_t ACfilter
 
volatile int32_t auxAC = 0
 

DC-bus voltage filter variables

volatile IIR_lowpass_int_t DCfilter
 
volatile int32_t auxDC = 0
 

Controller structures

volatile controller_int_t voltage_int_ctr
 
volatile controller_PI_t current_PI_ctr
 

Temperature variables

static volatile const uint16_t * temp_amb_dig
 

Time counters

uint8_t _1ms_count = 0
 
uint8_t _100ms_count = 0
 
uint8_t time_BOP = 0
 
uint8_t time_ACOK = 0
 
uint8_t time_PLD_68V = 0
 
uint8_t time_PLD_75V = 0
 
uint8_t time_V_step = 0
 
uint8_t time_INIT = 30
 
uint8_t time_extra_bulk = 0
 

Input voltage monitoring flags

static bool BOP_flag_75V = false
 
static bool BOP_flag_68V = false
 

Detailed Description

Function Documentation

void control_loop_init ( void  )

Assign value to the coefficients of voltage and current loops.
Reset the state and output of both controllers.

Returns
None
void delay_100us ( uint32_t  time)

Delay function.

Parameters
timeWait time in multiples of 100us
Returns
None
void fan_control_temp_protection ( void  )

Temperature monitoring: protection and fan control.

Returns
None
void IIR_param_init ( void  )

IIR coefficients initialization.
IIR cascaded low-pass filter of the AC voltage to obtain the RMS value.
IIR notch filter of the DC voltage to remove 100/120Hz ripple.
Sampling frequency of both filters is 3250Hz, every 2 cycles of CCU40.CC41 @ 6.5kHz.

Returns
None
void input_voltage_observer ( void  )

BOP protection, checking AVG input voltage.
The function modifies the control status register.

Returns
None
void MATH_DIV_config ( void  )

DIV kernel of the MATH co-processor initialization.
Used in the input RMS feedforward.

Returns
None
void temperature_sense_enable ( void  )
inline

Enable the internal temperature sensor and set the measurement pointer.

Returns
None
void time_counter ( void  )

Time counter is a background process to count "real-time" in the application.

Returns
None

Variable Documentation

uint8_t _100ms_count = 0

100ms counter.

uint8_t _1ms_count = 0

1ms counter.

volatile IIR_lowpass_int_t ACfilter

Filter instance

volatile int32_t auxAC = 0

Scaled AC voltage for filter operation

volatile int32_t auxDC = 0

Scaled DC voltage for filter operation

bool BOP_flag_68V = false
static

PLD voltage flag.

bool BOP_flag_75V = false
static

PLD voltage flag.

volatile controller_PI_t current_PI_ctr

Current controller.

volatile IIR_lowpass_int_t DCfilter

Filter instance

volatile bool power_stage_ON = false

State Machine fixes if the Power Stage (PWM) can be turned on or it must be turned off.

volatile const uint16_t* temp_amb_dig
static

Ambient temperature from XMC die.

uint8_t time_ACOK = 0

Not used, debugging of LCDO detection

uint8_t time_BOP = 0

Not used, debugging of start-up sequence

uint8_t time_extra_bulk = 0

Counter to increase bulk reference after AC lost (LCDO).

uint8_t time_INIT = 30

Counter to start/resume operation.

uint8_t time_PLD_68V = 0

Counter for PLD timing definition.

uint8_t time_PLD_75V = 0

Counter for PLD timing definition.

uint8_t time_V_step = 0

Counter to define time step between voltage ramp in PFC soft-start.

volatile controller_int_t voltage_int_ctr

Voltage controller.