3.3kW Totem-pole PFC with CoolMOS and XMC1402
|
#include <communication.h>
Data Fields | |
| uint16_t | dt_d2s |
| uint16_t | dt_s2d_MAX |
| uint16_t | dt_s2d_MIN |
| uint16_t | dt_const_iLimit |
| uint16_t | dt_s2d_offreg1 |
| uint16_t | dt_s2d_slopereg1 |
| uint16_t | dt_reg1_iLimit |
| uint16_t | dt_s2d_offreg2 |
| uint16_t | dt_s2d_slopereg2 |
| uint16_t | dt_reg2_iLimit |
| uint16_t | power_target |
| uint16_t | master_key |
Converter parameters
| uint16_t params_t::dt_const_iLimit |
Current limit for maximum dead time application. [CLK_units]
| uint16_t params_t::dt_d2s |
Diode to switch dead time. [CLK_units]
| uint16_t params_t::dt_reg1_iLimit |
Current limit for linear region 1 dead time application. [CLK_units]
| uint16_t params_t::dt_reg2_iLimit |
Current limit for linear region 2 dead time application. [CLK_units]
| uint16_t params_t::dt_s2d_MAX |
Maximum switch to diode (S2D) dead time. [CLK_units]
| uint16_t params_t::dt_s2d_MIN |
Minimum switch to diode (S2D) dead time. [CLK_units]
| uint16_t params_t::dt_s2d_offreg1 |
Linear region 1 offset for S2D dead time calculation. [CLK_units]
| uint16_t params_t::dt_s2d_offreg2 |
Linear region 2 offset for S2D dead time calculation. [CLK_units]
| uint16_t params_t::dt_s2d_slopereg1 |
Linear region 1 slope for S2D dead time calculation. [CLK_units]
| uint16_t params_t::dt_s2d_slopereg2 |
Linear region 2 slope for S2D dead time calculation. [CLK_units]
| uint16_t params_t::master_key |
Key used to store the first upload of the software a set of default parameters.
| uint16_t params_t::power_target |
Power target to match the communication requirement.