3.3kW Totem-pole PFC with SiC and XMC1404
 All Data Structures Files Functions Variables Typedefs Enumerations Enumerator Macros Groups Pages
control_interrupts.c File Reference

Control related interrupts code. More...

#include <DAVE.h>
#include "LLD_conf_code/adc.h"
#include "control_interrupts.h"
#include "init_bckgnd_funct.h"

Functions

void current_loop_ISR (void)
 Current loop interrupt.
CR2 while counting up in CCU80.CC81 (PWM-PFC) triggers the ADC queue.
A result event of the queue triggers this interrupt.
Prio 1. More...
 
void current_ref_ISR (void)
 Current reference interrupt.
pwm_count counts number of PWM cycles.
PR event of pwm_count triggers the current_fed_ISR() at a defined number of switching cycles.
Prio 2. More...
 
void voltage_loop_ISR (void)
 Voltage control interrupt.
Timer CCU40.CC42 triggers this interrupt in the period match event.
IIR low-pass filter of the AC voltage to obtain the RMS value.
IIR notch filter of the DC voltage to remove 100/120 Hz component.
Voltage loop and voltage monitoring.
State machine for start-up and event management.
Prio 3. More...
 

Variables

static volatile uint8_t i_filter = 0
 
volatile PFC_var_t PFC
 
volatile uint16_t time_count_5kHz = 0
 
ADC results
volatile uint32_t * ADCResult_iL
 
volatile uint32_t * ADCResult_DCBus
 
volatile uint32_t * ADCResult_VAC
 
volatile uint32_t * ADCResult_Temp
 
volatile uint32_t * ADCResult_BOP
 
Control and Fault status registers
volatile state_t status_reg = ST_INIT
 
volatile fault_t fault_reg = F_INIT
 

Detailed Description

Control related interrupts code.

Author
Meneses Herrera, David; Escudero Rodriguez, Manuel
Date
12.11.2019
totempole_sensing.png
3300W Bidirectional Totem-pole CCM sensing and ground positioning.


TPPFC_control_concept.png
3300W Bidirectional Totem-pole CCM control structure.