3.3kW Totem-pole PFC with CoolMOS and XMC1402
|
Header of the functions for SW initialization and running in the background during operation. More...
#include <DAVE.h>#include "xmc_flash.h"Go to the source code of this file.
Data Structures | |
| struct | IIR_lowpass_int |
| struct | controller_PI |
| struct | controller_int |
Macros | |
| #define | CLK_CORE_HZ 48000000UL |
CORDIC configuration | |
| #define | DIV_AUTO_START 0 |
| #define | UNSIGNED_DIVISION 4 |
| #define | SIGNED_DIVISION 0 |
| #define | DIV_32BIT_BY_32BIT 0 |
Duty cycle limitation | |
| #define | MAX_DUTY 1453 |
| #define | MIN_DUTY 11 |
| #define | MAX_DELTA_DUTY (MAX_DUTY >> 1) |
| #define | MAX_DUTY_LCDO 1387 |
Input voltage range for BOP | |
| #define | VIN_MIN_START_INIT 2530 |
| #define | VIN_MIN_START 2530 |
| #define | VIN_MIN_PLD_130V 2133 |
| #define | VIN_MIN_PLD_150V 2500 |
| #define | VRMS_MIN_LIMIT 1176 |
Current limit | |
| #define | I_IN_AVG_MAX 17882 |
Temperature and fan control | |
Maximum current representation Multiplication factor during bulk undershoot (applied shift) Multiplication factor applied if reference under certain limit | |
| #define | T_MIN_ADC 1945 |
| #define | T_CORNER_ADC 301 |
| #define | T_UC_ZERO_ADC 2225 |
| #define | T_UC_SLOPE_ADC 1170 |
| #define | T_OC_ZERO_ADC 589 |
| #define | T_OC_SLOPE_ADC 7959 |
| #define | T_MIN_PWM 40 |
| #define | T_MAX_PWM 65 |
| #define | PR_FAN_PWM (fan_pwm.config_ptr->period_value) |
| #define | T_SLOPE_PWM (PR_FAN_PWM/(T_MAX_PWM-T_MIN_PWM)) |
| #define | FAN_MS (80) |
Timing definition | |
| #define | LIMIT_1_MILI_S 5 |
| #define | LIMIT_100_MILI_S 100 |
Typedefs | |
| typedef struct IIR_lowpass_int | IIR_lowpass_int_t |
| typedef struct controller_PI | controller_PI_t |
| typedef struct controller_int | controller_int_t |
Functions | |
| void | IIR_param_init (void) |
| IIR coefficients initialization. IIR cascaded low-pass filter of the AC voltage to obtain the RMS value. IIR notch filter of the DC voltage to remove 100/120Hz ripple. Sampling frequency of both filters is 2500Hz, every 2 cycles of CCU40.CC41 @ 5kHz. More... | |
| void | MATH_DIV_config (void) |
| DIV kernel of the MATH co-processor initialization. Used in the input RMS feedforward. More... | |
| void | control_loop_init (void) |
| Assign value to the coefficients of voltage and current loops. Reset the state and output of both controllers. Reset current offset calculation variables. Set initial power for inverter operation. More... | |
| void | time_counter (void) |
| Time counter is a background process to count "real-time" in the application. More... | |
| void | delay_100us (uint32_t time) |
| Delay function. More... | |
| void | PFC_INV_mode (void) |
| Operation mode (PFC - AC/DC or inverter - DC/AC) selection function. Decision taken only once when starting the application. OPERATION MODE FIXED TO PFC!!! More... | |
| void | input_voltage_observer (void) |
| BOP protection, checking AVG input voltage. The function modifies the control status register. More... | |
| void | fan_control_temp_protection (void) |
| Temperature monitoring: protection and fan control. More... | |
| void | flash_sleep_ctr () |
| Flash memory sleep state control. More... | |
Variables | |
| volatile IIR_lowpass_int_t | ACfilter |
| volatile IIR_lowpass_int_t | DCfilter |
| volatile int32_t | auxAC |
| volatile int32_t | auxDC |
| volatile uint16_t | time_count_5kHz |
| uint8_t | _1ms_count |
| uint8_t | _100ms_count |
| uint8_t | time_BOP |
| uint8_t | time_ACOK |
| uint8_t | time_PLD_130V |
| uint8_t | time_PLD_150V |
| uint8_t | time_V_step |
| uint16_t | time_INIT |
| uint8_t | time_extra_bulk |
| volatile bool | power_stage_ON |
| volatile bool | current_loop_ON |
| volatile controller_int_t | voltage_int_ctr |
| volatile controller_PI_t | current_PI_ctr |
Header of the functions for SW initialization and running in the background during operation.
| #define CLK_CORE_HZ 48000000UL |
CLK frequency (Hz)
| #define DIV_32BIT_BY_32BIT 0 |
This sets 32-bit divide by 32-bit
| #define DIV_AUTO_START 0 |
Calculation is automatically started with a write to DVS register
| #define FAN_MS (80) |
Fan control clock timer. [_1ms_count]
| #define I_IN_AVG_MAX 17882 |
Maximum current limitation
| #define LIMIT_100_MILI_S 100 |
100ms @ 1ms counter
| #define LIMIT_1_MILI_S 5 |
1ms @ 5kHz
| #define MAX_DELTA_DUTY (MAX_DUTY >> 1) |
Maximum allowed duty cycle variation of the control loop
| #define MAX_DUTY 1453 |
Maximum allowed duty cycle during operation
| #define MAX_DUTY_LCDO 1387 |
Maximum allowed duty cycle after AC lost
| #define MIN_DUTY 11 |
Minimum allowed duty cycle during operation
| #define PR_FAN_PWM (fan_pwm.config_ptr->period_value) |
Fan PWM period
| #define SIGNED_DIVISION 0 |
Signed division is selected
| #define T_CORNER_ADC 301 |
Corner temperature for linear approximation change
| #define T_MAX_PWM 65 |
Maximum temperature for fan PWM linear variation [Celsius]
| #define T_MIN_ADC 1945 |
Minimum temperature [ADC]
| #define T_MIN_PWM 40 |
Minimum temperature for fan PWM linear variation [Celsius]
| #define T_OC_SLOPE_ADC 7959 |
Linear approx over corner temperature: slope
| #define T_OC_ZERO_ADC 589 |
Linear approx over corner temperature: value at 0°C
| #define T_SLOPE_PWM (PR_FAN_PWM/(T_MAX_PWM-T_MIN_PWM)) |
Slope definition for fan PWM linear variation
| #define T_UC_SLOPE_ADC 1170 |
Linear approx under corner temperature: slope
| #define T_UC_ZERO_ADC 2225 |
Linear approx under corner temperature: value at 0°C
| #define UNSIGNED_DIVISION 4 |
Unsigned division is selected
| #define VIN_MIN_PLD_130V 2133 |
145Vrms; 0.5s if the voltage is between 127V and 150V (Power line disturbance)
| #define VIN_MIN_PLD_150V 2500 |
170Vrms; 2s if the voltage is between 150V and 175V (Power line disturbance)
| #define VIN_MIN_START 2530 |
172Vrms, converter start threshold
| #define VIN_MIN_START_INIT 2530 |
172Vrms, converter start threshold
| #define VRMS_MIN_LIMIT 1176 |
80Vrms; RMS voltage to limit the 1/RMS^2 calculation.
| typedef struct controller_int controller_int_t |
Voltage controller structure
| typedef struct controller_PI controller_PI_t |
Controller structure for current loop
| typedef struct IIR_lowpass_int IIR_lowpass_int_t |
IIR filter structure, used in AC-RMS and DC-Notch filtering