Started at 2021-11-15 20:01:07
Successfully connected to TC39x B-step (JTAG ID 0x20205083)
Resets are allowed
Access HW is DAS JDS Application Kit TC397 V2.0 AK2QZS5B (30 MHz)
Access HW supports on-chip trace and unreliable continuous trace
Access protocol is DAP
Device Unique ID (UID) is 0x0a0d0040, 0x50000017, 0x412381df, 0x00000000
UID 16 bit hash is 0xF03B
System clock frequency is 300 MHz (measurement accuracy 0.22 MHz)
Checking for CPU software writes to on-chip debug and trace modules
Device was reset and then observed for 230.0 ms
CPU(s) write to ['CBS_COMDATA']
Refer to soh_WrittenByCpu for more details
Checking the clock system configuration
Oscillator is in frequency range (OSCCON.PLLxV bits set)
System PLL is locked and not in power saving mode
System PLL frequency modulation is not active
Peripheral PLL is locked and not in power saving mode
Clock frequencies {'SRI': 300.0, 'SPB': 100.0, 'STM': 100.0, 'FSI': 100.0, 'FSI2': 300.0, 'BBB': 150.0, 'CPU0': 300.0, 'CPU1': 300.0, 'CPU2': 300.0, 'CPU3': 300.0, 'CPU4': 300.0, 'CPU5': 300.0}
Device was reset and then observed for more than param_TimeStartup_ms (10.0 ms)
Observation time was 13.1 ms
Trace file: ./LogsDemo/TC39x_F03B/trace/CclTc3xxChkClkBasic.mcds
Startup sequence is valid. All CCU write accesses are by CPU0.
0.150 ms Oscillator start
0.322 ms PLLs locked
0.361 ms (35105 MCDS ticks) source0 frequency set to 150.0 MHz
Waited 0.104 ms after 50.0 MHz frequency step (2.1 µs/MHz
0.465 ms (42937 MCDS ticks) source0 frequency set to 200.0 MHz
Waited 0.103 ms after 50.0 MHz frequency step (2.1 µs/MHz
0.568 ms (53270 MCDS ticks) source0 frequency set to 300.0 MHz
Please note that trace tools usually do not consider frequency changes for their trace message time stamps
Clock startup is within param_MaxClkStartupTime_ms (1.000 ms)
Checking CPU basics
Used CPUs are [0, 1, 2, 3, 4, 5], unused are []
ERROR: soH_CpuNotUsed differs from param_CpuNotUsed
CPUs not using memory protection are [0, 1, 2, 3, 4, 5]
ERROR: soH_CpuMemProtNotEn differs from param_CpuMemProtNotEn
CPUs not using temporal protection are [0, 1, 2, 3, 4, 5]
ERROR: soH_CpuTempProtNotEn differs from param_CpuTempProtNotEn
FCD (Free Context List Depleted) trap bit not set for any CPU
All used CPUs are running
Checking CPU caches
Instruction cache is enabled for all CPUs
Instruction cache is using standard segments 8 and 9 for all CPUs
Data cache is enabled for all CPUs
Data cache is using standard segments 8 and 9 for all CPUs
Checking lockstep configuration
Device has 4 lockstep CPUs (0, 1, 2, 3)
Lockstep is enabled for all lockstep CPUs
Checking Flash wait cycles
ERROR: PFLASH wait cycles 12 not within margin (min 9, max 10)
ERROR: PFLASH ECC wait cycles 5 not within margin (min 3, max 3)
ERROR: DFLASH wait cycles 12 not within margin (min 10, max 10)
ERROR: DFLASH ECC wait cycles 5 not within margin (min 2, max 2)
Device was reset and then observed for more than param_TimeStartup_ms (10.0 ms)
Observation time was 13.7 ms
Trace file: ./LogsDemo/TC39x_F03B/trace/CclTc3xxChkFlashWaitCycles.mcds
Startup sequence is valid
DFLASH wait cycles are set by HF_DWAIT reset value
PFLASH wait cycles are set by HF_PWAIT reset value
Checking interrupt basics
CPU0 prio sorted interrupts are ['ASCLIN0ERR', 'ASCLIN0RX', 'ASCLIN0TX']
CPU0 uses only unique interrupt priorities
No interrupts mapped to CPU1
No interrupts mapped to CPU2
No interrupts mapped to CPU3
No interrupts mapped to CPU4
No interrupts mapped to CPU5
No interrupts mapped to DMA
No interrupt trigger overflow detected
Checking CLC register settings
Clock enabled by SW for ['ASCLIN0_CLC', 'EMEM_CLC']
ERROR: soH_ClcEnabledBySw differs from param_ClcEnabledBySw
Clock disabled by SW for []
Checking ACCEN register settings
ERROR: No ACCEN register was configured (disable this check if this is intended)